Mylex eXtremeRAID Guia de Instalação Página 144

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 210
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 143
Enclosure Monitoring and Management
5-28 GAM Client v3.00 and WSAM Users Manual
way
OK - The UPS is optimal. Three additional items are displayed with
this state: AC Pwr - the UPS is reporting an AC power failure; DC
Pwr - the UPS is reporting a DC power failure; Low Bat - the UPS
can power the system for only 2 to 5 more minutes.
Failed - The UPS is installed, but has failed
Error status for troubleshooting purposes. Error status for an enclosure
is reported in a format similar to the following example:
0 Addressing 25 02:03 04:05
0 is the error number
Addressing is the error type
25 is the ALPA (Arbitrated Loop - Port Address) of the drive in
question
02:03 is the first known channel and target to which the ALPA is
mapped
04:05 is the second known channel and target to which the ALPA is
mapped
An information field (may need to scroll, not visible in Figure 5-27
above), which contains most of the items listed on the Information
page, for easier cross-reference
Click the Close button to close the dialog box.
Vista de página 143
1 2 ... 139 140 141 142 143 144 145 146 147 148 149 ... 209 210

Comentários a estes Manuais

Sem comentários