Vista de página 201
Glossary
G-8 GAM Client v3.00 and WSAM Users Manual
Note
Ready State does not apply for Mylex External RAID
Controllers
Online: A disk drive is in an online state if it...
Is powered on; and
Has been defined as a member of a drive group; and
Is operating properly.
Standby: A disk drive is in a standby state if it...
Is powered on; and
Is able to operate properly; and
Was NOT defined as part of any drive group.
Dead: A disk drive is in a dead state if it...
Is not present; or
If it is present but not powered on; or
If it failed to operate properly and was killed by the controller.
When the controller detects a failure on a disk, it kills that disk by
changing its state to dead. A drive in a dead state does not participate in
any I/O activity. No commands are issued to dead drives.
Rebuild: A disk drive is in a rebuild state...
While it is in the process of being rebuilt. During this process, data is
regenerated and written to the disk drive. This state is sometimes referred to
as Write-Only (WRO).
RAID
RAID stands for Redundant Array of Independent Disks. Several different
forms of RAID implementation have been defined. Each form is usually
referred to as a RAID level. The basic RAID levels supported by Mylex
Disk Array Controllers are shown below.